Aina 11 za Pathojeni ya Kupumua

Maelezo Fupi:

Seti hii hutumika kwa utambuzi wa ubora wa in vitro wa vimelea vya kawaida vya upumuaji katika makohozi ya binadamu, ikiwa ni pamoja na Haemophilus influenzae (HI), Streptococcus pneumoniae (SP), Acinetobacter baumannii (ABA), Pseudomonas aeruginosa (PA), Klebsiella Pneumoniae (KPN) Klebsiella Pneumoniae (KPN) pertussis (BP), Bacillus parapertusss (Bpp), Mycoplasma pneumoniae (MP), Klamidia pneumoniae (Cpn), Legionella pneumophila (Mguu). Matokeo yanaweza kutumika kama msaada katika utambuzi wa wagonjwa waliolazwa hospitalini au wagonjwa mahututi wanaoshukiwa kuwa na maambukizo ya bakteria ya njia ya upumuaji.Seti hii hutumika kwa utambuzi wa ubora wa in vitro wa vimelea vya kawaida vya upumuaji katika makohozi ya binadamu, ikiwa ni pamoja na Haemophilus influenzae (HI), Streptococcus pneumoniae (SP), Acinetobacter baumannii (ABA), Pseudomonas aeruginosa (PA), Klebsiella Pneumoniae (KPN) Klebsiella Pneumoniae (KPN) pertussis (BP), Bacillus parapertusss (Bpp), Mycoplasma pneumoniae (MP), Klamidia pneumoniae (Cpn), Legionella pneumophila (Mguu). Matokeo yanaweza kutumika kama msaada katika utambuzi wa wagonjwa waliolazwa hospitalini au wagonjwa mahututi wanaoshukiwa kuwa na maambukizo ya bakteria ya njia ya upumuaji.


Maelezo ya Bidhaa

Lebo za Bidhaa

Jina la bidhaa

HWTS-RT162A Aina 11 za Kitengo cha Kugundua Asidi ya Nyuklia ya Kupumua(Fluorescence PCR)

Kituo

靶标 Kituo
核酸反应液A 核酸反应液B 核酸反应液C 核酸反应液D
HI Smet MP Mguu FAM
SP PA Bp / CY5
KPN ABA Bpp Cpn ROX
内参 内参 内参 内参 VIC/HEX

Epidemiolojia

Maambukizi ya njia ya upumuaji ni kundi muhimu la magonjwa ambayo yana tishio kubwa kwa afya ya binadamu, na tafiti zimeonyesha kuwa maambukizi mengi ya njia ya upumuaji husababishwa na vimelea vya bakteria na au virusi vinavyoambukiza mwenyeji, na kusababisha kuongezeka kwa ukali wa ugonjwa huo na hata kifo, hivyo kufafanua pathojeni inaruhusu matibabu yaliyolengwa na kuboresha kiwango cha maisha cha mgonjwa.[1,2].

Vigezo vya Kiufundi

Hifadhi

≤-18℃

Maisha ya rafu Miezi 12
Aina ya Kielelezo Makohozi
Ct HI,SP,KPN,PA,ABA,Smet:Ct≤33BP,Bpp,MP,Cpn,Mguu:Ct≤38
CV <5.0%
LoD Klebsiella pneumoniae, Streptococcus pneumoniae, Haemophilus influenzae, Pseudomonasaeruginosa, Acinetobacter baumannii, Stenotrophomonas maltophilia na Legionellapneumophila: 1000 CFU/mL;

Bordetella pertussis na Bacillus parapertussis: 500 CFU/mL;

Mycoplasma pneumoniae na Klamidia pneumoniae: nakala 200/mL.

Umaalumu Matokeo ya mtihani wa utendakazi mtambuka yalionyesha kuwa hakukuwa na majibu tofauti kati ya kifaa hiki na Cytomegalovirus, Herpes simplex virus aina 1, Varicella-zoster virus, Epstein-Barr virus, Bordetella pertussis, Corynebacterium, Escherichia coli, Haemophilus influenzae, Lactobacillus, Legionella-zoster virus, Legionellautten camolauxellauxelles Kifua kikuu cha Mycobacterium, Neisseria meningitidis, Neisseria, Pseudomonas aeruginosa, Staphylococcus aureus, Staphylococcus epidermidis, Streptococcus pyogenes, Streptococcus salivarius, Acinetobacter baumannii,Stenotrophiliamonasbacterium Burgers striatum, Nocardia, Serratia marcescens, Citrobacter, Cryptococcus, Aspergillus fumigatus, Aspergillus flavus, Pneumocystis jiroveci, Candida albicans, Rothia mucilaginosus, Streptococcus oralis, Klebsiella pneumoniae, Klebsiella pneumoniae, Chlamydia nuksia ya binadamu na Chlamydia pneumonia.
Vyombo Vinavyotumika Applied Biosystems 7500 Mifumo ya PCR ya Wakati Halisi

Applied Biosystems 7500 Fast Real-Time PCR Systems

QuantStudio®Mifumo 5 ya PCR ya Wakati Halisi

SLAN-96P Mifumo ya PCR ya Wakati Halisi

LightCycler®480 Mfumo wa PCR wa Wakati Halisi

LineGene 9600 Plus Mifumo ya Kugundua PCR ya Wakati Halisi

MA-6000 ya Muda Halisi ya Kiasi cha Baiskeli ya Joto

Mfumo wa PCR wa BioRad CFX96 wa Wakati Halisi

Mfumo wa PCR wa BioRad CFX Opus 96 wa Wakati Halisi

Mtiririko wa Kazi

DNA/RNA Kit ya Jumla ya Macro & Micro-Test (HWTS-3019) (ambayo inaweza kutumika pamoja na Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)) na Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Ongeza L20kifiziolojiachumvi kwa precipitate iliyosindika, na hatua zinazofuata zinapaswa kufanywa kwa mujibu wa maagizo. Kiwango cha juu kinachopendekezwa ni 100 µL.


  • Iliyotangulia:
  • Inayofuata:

  • Andika ujumbe wako hapa na ututumie