Aina 11 za Vimelea vya Kupumua

Maelezo Mafupi:

Kifaa hiki kinatumika kwa ajili ya kugundua vimelea vya kawaida vya kupumua ndani ya vitro katika makohozi ya binadamu, ikiwa ni pamoja na Haemophilus influenzae (HI), Streptococcus pneumoniae (SP), Acinetobacter baumannii (ABA), Pseudomonas aeruginosa (PA), Klebsiella Pneumoniae (KPN), Stenotrophomonas maltophilia (Smet), Bordetella pertussis (BP), Bacillus parapertuss (Bpp), Mycoplasma pneumoniae (MP), Chlamydia pneumoniae (Cpn), Legionella pneumophila (Leg). Matokeo yanaweza kutumika kama msaada katika utambuzi wa wagonjwa waliolazwa hospitalini au wagonjwa mahututi wenye maambukizi ya bakteria yanayoshukiwa kuwa ya njia ya upumuaji.Kifaa hiki kinatumika kwa ajili ya kugundua vimelea vya kawaida vya kupumua ndani ya vitro katika makohozi ya binadamu, ikiwa ni pamoja na Haemophilus influenzae (HI), Streptococcus pneumoniae (SP), Acinetobacter baumannii (ABA), Pseudomonas aeruginosa (PA), Klebsiella Pneumoniae (KPN), Stenotrophomonas maltophilia (Smet), Bordetella pertussis (BP), Bacillus parapertuss (Bpp), Mycoplasma pneumoniae (MP), Chlamydia pneumoniae (Cpn), Legionella pneumophila (Leg). Matokeo yanaweza kutumika kama msaada katika utambuzi wa wagonjwa waliolazwa hospitalini au wagonjwa mahututi wenye maambukizi ya bakteria yanayoshukiwa kuwa ya njia ya upumuaji.


Maelezo ya Bidhaa

Lebo za Bidhaa

Jina la bidhaa

HWTS-RT162A Aina 11 za Kifaa cha Kugundua Asidi ya Nyuklia ya Vimelea vya Pumua(PCR ya Mwangaza)

Kituo

靶标 Kituo
核酸反应液A 核酸反应液B 核酸反应液C 核酸反应液D
HI Smet MP Mguu FAM
SP PA Bp / CY5
KPN ABA Bpp Cpn ROX
内参 内参 内参 内参 VIC/HEX

Epidemiolojia

Maambukizi ya njia ya upumuaji ni kundi muhimu la magonjwa ambayo ni tishio kubwa kwa afya ya binadamu, na tafiti zimeonyesha kuwa maambukizi mengi ya njia ya upumuaji husababishwa na bakteria na virusi vinavyoambukiza pamoja mwenyeji, na kusababisha kuongezeka kwa ukali wa ugonjwa na hata kifo, kwa hivyo kufafanua pathojeni huruhusu matibabu lengwa na kuboresha kiwango cha kuishi kwa mgonjwa.[1,2].

Vigezo vya Kiufundi

Hifadhi

≤-18℃

Muda wa kukaa rafu Miezi 12
Aina ya Sampuli Makohozi
Ct HI、SP、KPN、PA、ABA、Smet:Ct≤33BP、Bpp、MP、Cpn、Mguu:Ct≤38
CV <5.0%
LoD Klebsiella pneumoniae, Streptococcus pneumoniae, Haemophilus influenzae, Pseudomonasaeruginosa, Acinetobacter baumannii, Stenotrophomonas maltophilia na Legionellapneumophila: 1000 CFU/mL

Bordetella pertussis na Bacillus parapertussis: 500 CFU/mL;

Mycoplasma pneumoniae na Klamidia pneumoniae: nakala 200/mL.

Umaalum Matokeo ya jaribio la mtambukano yalionyesha kuwa hakukuwa na mmenyuko mtambuka kati ya kit hiki na Cytomegalovirus, aina ya 1 ya virusi vya Herpes simplex, virusi vya Varicella-zoster, virusi vya Epstein-Barr, Bordetella pertussis, Corynebacterium, Escherichia coli, Haemophilus influenzae, Lactobacillus, Legionella pneumophila, Moraxella catarrhalis, aina zilizopunguzwa za kifua kikuu cha Mycobacterium, Neisseria meningitidis, Neisseria, Pseudomonas aeruginosa, Staphylococcus aureus, Staphylococcus epidermidis, Streptococcus pyogenes, Streptococcus salivarius, Acinetobacter baumannii, Stenotrophomonas maltophilia, Burkholderia cepacia, Corynebacterium striatum, Nocardia, Serratia marcescens, Citrobacter, Cryptococcus, Aspergillus fumigatus, Aspergillus flavus, Pneumocystis jiroveci, Candida albicans, Rothia mucilaginosus, Streptococcus oralis, Klebsiella pneumoniae, Klamydia psittaci, Coxiella burnetii na asidi za kiini za jenomu za binadamu.
Vyombo Vinavyotumika Mifumo ya Biosystems 7500 ya Muda Halisi ya PCR

Mifumo ya PCR ya Muda Halisi ya Biosystems 7500 Inayotumika

QuantStudio®Mifumo 5 ya PCR ya Wakati Halisi

Mifumo ya PCR ya Wakati Halisi ya SLAN-96P

Kisafirishaji cha Mwanga®Mfumo wa PCR wa Muda Halisi wa 480

Mifumo ya Kugundua PCR ya LineGene 9600 Plus ya Wakati Halisi

Kipimajoto cha Muda Halisi cha MA-6000

Mfumo wa PCR wa BioRad CFX96 wa Muda Halisi

Mfumo wa PCR wa BioRad CFX Opus 96 wa Muda Halisi

Mtiririko wa Kazi

Kifaa cha Jumla cha DNA/RNA cha Macro & Micro-Test (HWTS-3019) (ambacho kinaweza kutumika pamoja na Kiondoa Asidi ya Nyuklia Kiotomatiki cha Macro & Micro-Test (HWTS-3006C, HWTS-3006B)) kutoka Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Ongeza 200µL yakisaikolojiaSaline kwenye sehemu iliyosindikwa, na hatua zinazofuata zinapaswa kufanywa kulingana na maelekezo. Kiasi kilichopendekezwa cha suluhisho ni 100 µL.


  • Iliyotangulia:
  • Inayofuata:

  • Andika ujumbe wako hapa na ututumie